[Rhino@localhost (#28)] listactivealarms
Alarm 56875565751424514 (Node 101, 07-Dec-05 16:44:05.435): Major
[resources.cap-conductor.capra.noconnection] Lost connection to
backend localhost:10222
Alarm 56875565751424513 (Node 101, 07-Dec-05 16:41:04.326): Major
[rhino.license] License with serial ’107baa31c0e’ has expired.
Clearing alarms can be done individually for each alarm, or for an entire group of Alarms. To clear one alarm individually, use
the
clearAlarm
command with the alarm’s ID as follows:
[Rhino@localhost (#29)] clearalarm 56875565751424514
Alarm cleared.
To clear a whole group of alarms, use the
clearAlarms
command with the alarm category as the parameter:
[Rhino@localhost (#30)] clearalarms rhino.license
Alarms cleared.
11.2.2 Web Console
When using the Web Console, the Alarm MBean is situated at the top of the list of MBeans. Figure 11.1 shows the Alarm
MBean.
Figure 11.1: The Web Console showing the Alarms MBean
Here, several things are apparent:
• The
AllActiveAlarms
attribute is a list of all of the current active alarms.
• The
clearAlarm
button will clear the selected alarm.
Open Cloud Rhino 1.4.3 Administration Manual v1.1 76
Komentarze do niniejszej Instrukcji